Dingxin DLD660 600kW/750kVA Generator Set Installation and Operation Instruction Manual

dingxin 600kw/750kva generator set, shanghai mitsubishi engine, comap control system


Dingxin DLD660 600kW/750kVA Generator Set Installation and Operation Instruction Manual - cover page
Brand
鼎新电气
Category
Generator
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
299 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
850DF0329ED77C1A8DE0B7BF137D180D

About this manual

The Dingxin DLD660 is a 50 Hz generator set rated 600 kW / 750 kVA at prime power and 660 kW / 825 kVA at standby power, using a Shanghai Mitsubishi S6R2-PTAA-C engine with a 40 °C radiator and a ComAp control system (MRS10/MRS16/IC-NT). Standard configuration includes a U-steel base frame with integrated absorber, DC high-energy lead-acid start batteries, an output circuit breaker and an industrial muffler with ripple flex exhaust pipe.

This installation and operation instruction manual gives the generator set ratings, engine and alternator specifications, the ComAp control system description with its functions and protections, and the list of standard and optional accessories for the engine control system, ATS, fuel system, exhaust system, canopy and spare parts. It closes with the ISO 8528-1 definitions of prime power and standby power and the nominal power reference conditions.

What's inside

  • Generator set specification
  • Engine specification
  • Alternator specification
  • Engine control system
  • Control system
  • Optional accessories
  • Fuel system
  • Exhaust system
  • Canopy
  • Power definition

Specifications

Prime power (50 Hz)600 kW / 750 kVA
Standby power (50 Hz)660 kW / 825 kVA
Rated voltage400/230 V
Rated current1080/1188 A
Rated frequency50 Hz
Rated speed1500 r/min
Power factor0.8 (lagging)
Line systemThree-phase four-wire system
Fuel consumption rate206 g/kW·h (PRP), 208 g/kW·h (ESP)
Noise value<105 dB(A) at 1 m at set side
Dimensions, open type (L×W×H)4200×1800×2120 mm
Net weight, open type5800 kg without coolant and oil
Displacement29.96 L
Bore / stroke170/220 mm
Compression ratio14.1:1
Maximum output power710 kW
Protection gradeIP 23
Insulation classH
Excitation typeBrushless self excitation

Frequently asked questions

What fuel does the DLD660 generator set use?

The fuel specification and grade is 0# light diesel.

Which control system is fitted to the generator set?

A ComAp control system is used, listed as MRS10/MRS16/IC-NT, with the ComAp NT MRS 10 given as manufacturer and model.

What is the difference between prime power and standby power?

Prime power is available for an unlimited number of annual hours in variable load application, while standby power is the maximum power for supplying emergency power during a utility power interruption, for up to 500 hours of operation per year.

What are the rated voltage and frequency?

The rated voltage is 400/230 V and the rated frequency is 50 Hz.

Download PDF (299 KB)