This document is a brief instruction manual for the Awit servo adjustment procedure, which introduces how to confirm the drive and motor models, wiring, motor model code matching, wiring diagrams, basic function parameters, servo alarm codes, and electronic gear ratio setting steps
This Chinese brief instructions manual is for the Aiweitu ID100 servo drive. It states that it gives a simple explanation of wiring and commissioning, and that details should be adjusted according to actual requirements.
It covers confirming the drive and motor model and installation environment, A-type and B-type wiring, motor model code matching, control-signal wiring with external or internal 24 V power, basic function parameters, servo alarm codes and remedies, electronic gear ratio setting steps, and appendix wiring diagrams for P series and W1 series position and speed control. This manual is written in Chinese.
| Drive model | ID100 |
|---|---|
| Encoder lines per revolution constant | C = 2500 |
| Control methods | 0: position control; 1: speed control; 3: motor trial run; 4: motor zero test; 5: load inertia measurement; 9: position/speed switching |
| Positioning completion range | 0 to 30000 pulses; factory value 8 |
| Position error detection range | 0 to 300 ×100 pulses; factory value 200 |
| Speed proportional gain | 5 to 300 Hz; factory value 40 |
| Speed integral time constant | 1 to 300; factory value 20 |
The manual says to confirm that the servo drive and motor are the required models and to pay attention to the installation environment.
Set password parameter P-0 to 310; the manual gives 310 as the model code password.
The example gives G=(1×2500×4)/6000=5/3, so parameter P-12 is set to 5 and P-13 is set to 3.
Open B2 and B3, and connect the external regenerative resistor between B1 and B2.