Aiweitu ID100 Servo Drive Adjustment Procedure Brief Instructions

This document is a brief instruction manual for the Awit servo adjustment procedure, which introduces how to confirm the drive and motor models, wiring, motor model code matching, wiring diagrams, basic function parameters, servo alarm codes, and electronic gear ratio setting steps


Aiweitu ID100 Servo Drive Adjustment Procedure Brief Instructions - cover page
Brand
艾威图
Category
Automation control Equipment
Document type
User Manual
Language
Chinese
Pages
20
File format
PDF
File size
3.8 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
AF241C994FD568D9182B336E807031E4

About this manual

This Chinese brief instructions manual is for the Aiweitu ID100 servo drive. It states that it gives a simple explanation of wiring and commissioning, and that details should be adjusted according to actual requirements.

It covers confirming the drive and motor model and installation environment, A-type and B-type wiring, motor model code matching, control-signal wiring with external or internal 24 V power, basic function parameters, servo alarm codes and remedies, electronic gear ratio setting steps, and appendix wiring diagrams for P series and W1 series position and speed control. This manual is written in Chinese.

What's inside

  • Confirming drive and motor model and installation environment
  • A-type and B-type wiring
  • Motor model code matching
  • Control signal wiring with external 24 V power
  • Control signal wiring with internal 24 V power
  • Basic function parameters
  • Servo alarm codes, causes and remedies
  • Electronic gear ratio setting steps
  • Appendix: P series position and speed control wiring
  • Appendix: W1 series position and speed control wiring

Specifications

Drive modelID100
Encoder lines per revolution constantC = 2500
Control methods0: position control; 1: speed control; 3: motor trial run; 4: motor zero test; 5: load inertia measurement; 9: position/speed switching
Positioning completion range0 to 30000 pulses; factory value 8
Position error detection range0 to 300 ×100 pulses; factory value 200
Speed proportional gain5 to 300 Hz; factory value 40
Speed integral time constant1 to 300; factory value 20

Frequently asked questions

What should be checked before commissioning the ID100 servo drive?

The manual says to confirm that the servo drive and motor are the required models and to pay attention to the installation environment.

What password is used to change the model code parameter P-1?

Set password parameter P-0 to 310; the manual gives 310 as the model code password.

How is the electronic gear ratio set for 6000 input pulses per motor revolution?

The example gives G=(1×2500×4)/6000=5/3, so parameter P-12 is set to 5 and P-13 is set to 3.

How should an external regenerative resistor be connected?

Open B2 and B3, and connect the external regenerative resistor between B1 and B2.