DM542 is a professional two-phase hybrid digital stepper motor driver, which can adapt to domestic and foreign brands, current within 4.2A and below, external diameter 42, 57, 86mm four-wire, six-wire, eight-wire two-phase hybrid stepper motor. It is suitable for various small and medium-sized automatic equipment and instruments, such as engraving machine, marking machine, cutting machine, laser exposure, plotter, CNC machine tool, pick and place device and so on. It has the effect characteristics in the equipment where users expect large current, small noise and high resolution operation.
DD DM542 is a two-phase hybrid digital stepper motor driver for 4-, 6-, and 8-wire two-phase/four-phase hybrid stepper motors with currents up to 4.2 A and 1.8 or 0.9 degree step angles. It supports 20-50 VDC input, 1.0-4.2 A output current, and selectable microstepping from 2 to 125, with optocoupler-isolated single-ended pulse/direction inputs.
The manual covers terminal and wiring requirements, DIP-switch settings for microstepping, standby current, and working current, mechanical and environmental specifications, motor matching and wiring, supply voltage and current selection, common faults and remedies, and warranty terms. This manual is written in Chinese.
| Input voltage | 20-50 VDC |
|---|---|
| Output current | 1.0-4.2 A |
| External control signal voltage | 3.3-24 V |
| Pulse width | >1.2 us |
| Direction setup time | >=5 us |
| Subdivision settings | 2, 4, 8, 16, 32, 64, 128, 5, 10, 20, 25, 40, 50, 100, 125 |
| Standby current | Full current (SW4 ON) or half current (SW4 OFF) |
| Working current settings | 1.00, 1.46, 1.91, 2.37, 2.84, 3.31, 3.76, 4.20 A |
| Protections | Overheat, overcurrent, undervoltage lockout, input reverse-polarity protection |
| Motor compatibility | 4-, 6-, or 8-wire two-phase/four-phase hybrid stepper motors |
| Step angle | 1.8 or 0.9 degrees |
| Weight | 0.3 kg |
| Humidity | 40-90% RH |
| Vibration | 10-55 Hz / 0.15 mm |
| Cooling | Natural or forced air cooling |
The pulse width should be greater than 1.2 us.
The direction signal should be established at least 5 us before the pulse signal.
Yes, the ENA terminal can be left unconnected when this function is not needed.
Set SW4 to ON for full current or OFF for half current.