This manual provides detailed instructions on how to use closed loop stepper servo systems, including system wiring diagrams, operating steps, driver connector layout diagrams, driver and motor wiring, status indicator lights, pulse input mode and motor rotation direction setting rotary switches, position gain adjustment rotary switches, pulse per turn setting rotary switches, and positioning completion pulse error setting rotary switches.
The Techservo Astep Series Closed Loop Stepping System User Manual explains the system wiring diagram and usage steps. It shows the driver connector layout and describes connections for power, motor, encoder, and digital I/O signals.
The manual also covers the status indicator LED and the SW1 pulse input/rotation direction switch, SW2 position gain adjustment, SW3 pulses-per-revolution setting, and SW4 positioning completion pulse error setting. This manual is written in Chinese.
| Power supply voltage | 20–28 VDC for CSD28/42/57/60xxx; 40–65 VDC for CSD86xxx |
|---|---|
| Pulse input level | Default 5 V TTL; for 12 V input use Rx=1.2K, for 24 V input use Rx=3.3K |
| Encoder power supply | +5 VDC |
| Digital I/O isolation | Photoelectric isolation on all I/O signals |
| Factory default pulses per revolution | 10000 pulses/rev |
| Default position gain switch setting | Position 3 |
SW1 position 1 defaults to single-pulse mode, which is pulse + direction.
When the input signal level is 24 V, connect Rx = 3.3K in series.
The factory setting is 10000 pulses per revolution, so 10000 input pulses turn the motor one revolution.
When the driver alarms, input a low-level signal to the ARST pin to clear the alarm.