Techservo Astep Series Closed Loop Stepping System User Manual

This manual provides detailed instructions on how to use closed loop stepper servo systems, including system wiring diagrams, operating steps, driver connector layout diagrams, driver and motor wiring, status indicator lights, pulse input mode and motor rotation direction setting rotary switches, position gain adjustment rotary switches, pulse per turn setting rotary switches, and positioning completion pulse error setting rotary switches.


Techservo Astep Series Closed Loop Stepping System User Manual - cover page
Brand
Techservo
Category
stepping motor
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
648 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
D9A551D1DE2544791E909C1894C331E7

About this manual

The Techservo Astep Series Closed Loop Stepping System User Manual explains the system wiring diagram and usage steps. It shows the driver connector layout and describes connections for power, motor, encoder, and digital I/O signals.

The manual also covers the status indicator LED and the SW1 pulse input/rotation direction switch, SW2 position gain adjustment, SW3 pulses-per-revolution setting, and SW4 positioning completion pulse error setting. This manual is written in Chinese.

What's inside

  • System Wiring Diagram
  • Usage Steps
  • Driver Connector Layout
  • Driver and Motor Wiring
  • Digital I/O Control Signal Connector
  • Status Indicator LED
  • Pulse Input Mode and Motor Rotation Direction Switch SW1
  • Position Gain Adjustment Switch SW2
  • Pulses per Revolution Switch SW3
  • Positioning Completion Pulse Error Switch SW4

Specifications

Power supply voltage20–28 VDC for CSD28/42/57/60xxx; 40–65 VDC for CSD86xxx
Pulse input levelDefault 5 V TTL; for 12 V input use Rx=1.2K, for 24 V input use Rx=3.3K
Encoder power supply+5 VDC
Digital I/O isolationPhotoelectric isolation on all I/O signals
Factory default pulses per revolution10000 pulses/rev
Default position gain switch settingPosition 3

Frequently asked questions

What is the default pulse input mode for SW1?

SW1 position 1 defaults to single-pulse mode, which is pulse + direction.

What external resistor is required when the input signal is 24 V?

When the input signal level is 24 V, connect Rx = 3.3K in series.

What is the factory default setting for pulses per revolution?

The factory setting is 10000 pulses per revolution, so 10000 input pulses turn the motor one revolution.

How can an alarm be cleared?

When the driver alarms, input a low-level signal to the ARST pin to clear the alarm.