About this manual

This manual is for the Langke XK3150-Exd explosion-proof weight meter. It describes the instrument's hardware, appearance, interfaces, settings, calibration, wiring, maintenance, and serial communication.

The document is written in Chinese and includes explosion-proof precautions, parameter tables, error messages, and communication formats.

What's inside

  • Overview
  • Appearance description
  • Common functions
  • Calibration
  • Weight detection parameters
  • Wiring
  • Maintenance
  • Serial communication

Specifications

Explosion protection gradeExdIIBT6
Explosion-proof markingEx d [ia Ga] II B T6 Gb
Explosion-proof certificate numberGYB17.1388X
Power supply220 V AC
Sensor excitation voltage5 V DC ±5%
Sensor connectionsUp to 4 sensors of 350 Ω
Sensor sensitivity0 to 3.0 mV/V
Sensor wiring4-wire
Keyboard5 keys
Display6-digit red LED display
Operating temperature-10 °C to 40 °C
Relay outputs4 channels, AC 250 V 3 A
Switch inputsDry or active contacts, optically isolated, 2500 V isolation
Analog output4-20 mA / 0-5 V
Serial communicationRS232/RS485, 600 to 19200 bit/s
ADC conversion rate120 SPS

Frequently asked questions

What is the explosion-proof rating of the XK3150-Exd?

The manual lists the explosion protection grade as ExdIIBT6.

How many sensors can the XK3150-Exd connect?

It can connect up to four 350 Ω sensors.

What serial communication interfaces does it support?

It supports RS232 and RS485 at 600 to 19200 bit/s.

How do I restore default parameters?

During power-on self-test, set the calibration switch to ON and press the two keys shown; the display shows i.ALL.