Instruction manual introducing the features and characteristics, usage methods, wiring instructions and maintenance and maintenance of the XK3150-Exd type explosion-proof weight meter
This manual is for the Langke XK3150-Exd explosion-proof weight meter. It describes the instrument's hardware, appearance, interfaces, settings, calibration, wiring, maintenance, and serial communication.
The document is written in Chinese and includes explosion-proof precautions, parameter tables, error messages, and communication formats.
| Explosion protection grade | ExdIIBT6 |
|---|---|
| Explosion-proof marking | Ex d [ia Ga] II B T6 Gb |
| Explosion-proof certificate number | GYB17.1388X |
| Power supply | 220 V AC |
| Sensor excitation voltage | 5 V DC ±5% |
| Sensor connections | Up to 4 sensors of 350 Ω |
| Sensor sensitivity | 0 to 3.0 mV/V |
| Sensor wiring | 4-wire |
| Keyboard | 5 keys |
| Display | 6-digit red LED display |
| Operating temperature | -10 °C to 40 °C |
| Relay outputs | 4 channels, AC 250 V 3 A |
| Switch inputs | Dry or active contacts, optically isolated, 2500 V isolation |
| Analog output | 4-20 mA / 0-5 V |
| Serial communication | RS232/RS485, 600 to 19200 bit/s |
| ADC conversion rate | 120 SPS |
The manual lists the explosion protection grade as ExdIIBT6.
It can connect up to four 350 Ω sensors.
It supports RS232 and RS485 at 600 to 19200 bit/s.
During power-on self-test, set the calibration switch to ON and press the two keys shown; the display shows i.ALL.