HAS4000 Series Heat Generator User Manual, mainly introduces product safety, installation, operation, maintenance and other content.
This Chinese user manual covers the Hakko HAS4000 Series hot air generator, document number B2-2033-08, supplied without a controller. It explains setup, operation, inspection and maintenance of the HAS4020, HAS4030, HAS4531 and HAS4551 models, and warns that the unit has hot surfaces, rotating parts and high-voltage sections.
The manual opens with safety information and warnings, then gives the main specifications and outline dimensions, part names, installation site conditions, mounting and duct connection, air-volume adjustment with the damper plate, and electrical wiring with terminal block details and a wiring diagram. It closes with start/stop procedures, daily inspection and storage, troubleshooting, reference data and after-sales service information. This manual is written in Chinese.
| Models | HAS4020, HAS4030, HAS4531, HAS4551 |
|---|---|
| Product codes | HAS4020: 00700610; HAS4030: 00700620; HAS4531: 00700631; HAS4551: 00700641 |
| Power supply | Single-phase 200 V (HAS4020/HAS4030); three-phase 200 V (HAS4531/HAS4551) |
| Heater power | HAS4020: 2 kW; HAS4030: 3 kW; HAS4531: 3 kW; HAS4551: 5 kW |
| Outlet gas temperature range | HAS4020/HAS4030: ambient to 400 °C; HAS4531/HAS4551: ambient to 300 °C |
| Air flow (50/60 Hz) | 1.2/1.5 m3/min with inlet duct fitted (HAS4020/HAS4030); 2.0/2.4 m3/min without inlet duct (HAS4531/HAS4551) |
| Maximum static pressure (50/60 Hz) | 0.18/0.26 kPa (HAS4020/HAS4030); 0.30/0.43 kPa (HAS4531/HAS4551) |
| Noise at maximum air flow | 59/63 dB (HAS4020/HAS4030); 65/69 dB (HAS4531/HAS4551) |
| Inlet gas temperature | −10 °C to 150 °C |
| Blower motor rated voltage | Single-phase 200 V, 50/60 Hz |
| Weight | 11 kg (HAS4020/HAS4030); 15 kg (HAS4531/HAS4551) |
The HAS4020 and HAS4030 range from ambient temperature to 400 °C, while the HAS4531 and HAS4551 range from ambient temperature to 300 °C. The manual says the outlet gas temperature varies with operating conditions.
When recirculation is used, the inlet air must be set to 150 °C or below.
The site must be indoors, with ambient temperature of 0 to 40 °C, relative humidity of 80% or less, no dust, explosive or corrosive gas, and no sealing of the unit.
No, the unit is for indoor use only and must not be used outdoors where it is exposed to wind and rain.