Hakko HAS4000 Series Hot Air Generator User Manual

HAS4000 Series Heat Generator User Manual, mainly introduces product safety, installation, operation, maintenance and other content.


Hakko HAS4000 Series Hot Air Generator User Manual - cover page
Brand
八光
Category
Heater
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
766 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
0BA93A21A5D565C87FC8310E06A05E58

About this manual

This Chinese user manual covers the Hakko HAS4000 Series hot air generator, document number B2-2033-08, supplied without a controller. It explains setup, operation, inspection and maintenance of the HAS4020, HAS4030, HAS4531 and HAS4551 models, and warns that the unit has hot surfaces, rotating parts and high-voltage sections.

The manual opens with safety information and warnings, then gives the main specifications and outline dimensions, part names, installation site conditions, mounting and duct connection, air-volume adjustment with the damper plate, and electrical wiring with terminal block details and a wiring diagram. It closes with start/stop procedures, daily inspection and storage, troubleshooting, reference data and after-sales service information. This manual is written in Chinese.

What's inside

  • Foreword
  • Important Safety Information
  • Safety Precautions
  • Main Specifications
  • Outline Dimensions
  • Part Names
  • Installation Site Conditions
  • Installation (Main Unit, Connection Duct)
  • Air Volume Adjustment
  • Electrical Wiring and Wiring Diagram

Specifications

ModelsHAS4020, HAS4030, HAS4531, HAS4551
Product codesHAS4020: 00700610; HAS4030: 00700620; HAS4531: 00700631; HAS4551: 00700641
Power supplySingle-phase 200 V (HAS4020/HAS4030); three-phase 200 V (HAS4531/HAS4551)
Heater powerHAS4020: 2 kW; HAS4030: 3 kW; HAS4531: 3 kW; HAS4551: 5 kW
Outlet gas temperature rangeHAS4020/HAS4030: ambient to 400 °C; HAS4531/HAS4551: ambient to 300 °C
Air flow (50/60 Hz)1.2/1.5 m3/min with inlet duct fitted (HAS4020/HAS4030); 2.0/2.4 m3/min without inlet duct (HAS4531/HAS4551)
Maximum static pressure (50/60 Hz)0.18/0.26 kPa (HAS4020/HAS4030); 0.30/0.43 kPa (HAS4531/HAS4551)
Noise at maximum air flow59/63 dB (HAS4020/HAS4030); 65/69 dB (HAS4531/HAS4551)
Inlet gas temperature−10 °C to 150 °C
Blower motor rated voltageSingle-phase 200 V, 50/60 Hz
Weight11 kg (HAS4020/HAS4030); 15 kg (HAS4531/HAS4551)

Frequently asked questions

What outlet air temperature range can the HAS4000 Series be set to?

The HAS4020 and HAS4030 range from ambient temperature to 400 °C, while the HAS4531 and HAS4551 range from ambient temperature to 300 °C. The manual says the outlet gas temperature varies with operating conditions.

What inlet air temperature must be used in recirculation mode?

When recirculation is used, the inlet air must be set to 150 °C or below.

What conditions does the installation site have to meet?

The site must be indoors, with ambient temperature of 0 to 40 °C, relative humidity of 80% or less, no dust, explosive or corrosive gas, and no sealing of the unit.

Can the hot air generator be used outdoors?

No, the unit is for indoor use only and must not be used outdoors where it is exposed to wind and rain.