Hailin FKY8006A Micro-Mini Air Pump Series Product Manual

FKY micro-mini air pump series product manual this series is a double-use pump, that is, the air inlet can suck air and the exhaust port can blow air. The product has the characteristics of long life, low interference, stable speed function, protection function, etc. It has a wide range of uses, is maintenance-free, non-polluting transmission, allows the medium gas to be rich in water vapor, has good corrosion resistance, and is installed without restriction.


Hailin FKY8006A Micro-Mini Air Pump Series Product Manual - cover page
Brand
海霖
Category
Other products
Document type
User Manual
Language
Chinese
Pages
18
File format
PDF
File size
770 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
D5A55F9AFC126C5D8EED4FFCB0793852

About this manual

This document is the product manual for the FKY micro-mini air pump series from Chengdu Hailin Technology. It describes features such as dual suction and blowing operation, a brushless motor, speed stability, protection functions, and use in medical, analytical, and industrial instruments.

It provides technical parameters for model FKY8006A, including flow, vacuum, pressure, mass, reliability by version, input voltage tolerance, and starting current. It also covers wiring notes, precautions, a 3D diagram, and product appearance. This manual is written in Chinese.

What's inside

  • Product features
  • Technical parameters
  • Performance parameters
  • Reliability parameters
  • Version description
  • Wiring instructions
  • Motor starting current
  • Precautions
  • 3D diagram
  • Product appearance

Specifications

ModelFKY8006A
Rated voltage12 V DC or 24 V DC
Load current≤500 mA at 12 V DC; ≤210 mA at 24 V DC
Peak flow rate≥6 L/min
Average flow rate≥3.5 L/min
Relative vacuum≥40 kPa
Mass≈280 g
Full-load life5000 h (simplified), 8000 h (standard), 12000 h (quality)
No-load life8000 h (simplified), 12000 h (standard), 18000 h (quality)
Motor life10000 h (simplified), 15000 h (standard), 20000 h (quality)
Input voltage tolerance12 V ±10%, 24 V ±5%
Reference test conditions20°C, 101.325 kPa
Life test environment5–33°C, 50–85% relative humidity
Media contact materialsReinforced nylon, EPDM rubber
Maximum starting current5.5 A at 12 V DC (<30 ms); 2.5 A at 24 V DC (<20 ms)
VersionsSimplified, standard, quality

Frequently asked questions

What is the FKY8006A rated voltage and load current?

It is rated for 12 V DC with load current up to 500 mA, or 24 V DC with load current up to 210 mA.

What are the life ratings for the simplified, standard, and quality versions?

Full-load life is 5000, 8000, and 12000 hours; no-load life is 8000, 12000, and 18000 hours; motor life is 10000, 15000, and 20000 hours.

What is the maximum motor starting current?

At 12 V DC it reaches 5.5 A for less than 30 ms; at 24 V DC it reaches 2.5 A for less than 20 ms.

What precautions are given for using the pump?

It has no waterproof, dustproof, or explosion-proof protection; keep solids out of the medium; re-seal when pumping harmful gas; use a high-quality DC power supply; and avoid hot plugging.

Download PDF (770 KB)