KYX-D001 radar application manual, introduces the product's features, quick test guide, interface protocol, data analysis examples and other content
This is the V2.4 application manual for the KYX-D001 radar sensor from Shenzhen Kaiyangxing Information Technology, a millimeter-wave radar solution supplier. The sensor stays in sleep mode after power-up and is woken either by a serial wake command or by a rising edge on the GPIO pin; after each wake it takes one measurement of parking space occupancy and signal strength, sends the data over the serial port, and returns to sleep. The manual covers the product functions, a quick test procedure, the interface protocol and worked parsing examples.
The quick test section shows how to connect the sensor through a USB-to-serial module (3.3 V port with more than 100 mA drive capability), how to configure the serial assistant at 115200 baud, 8 data bits, 1 stop bit, no parity and no flow control, and how to send the wake command. The protocol section defines the RadarConfiguration, RadarFeedback and TargetStatus messages with their frame headers, command IDs, checksums and frame tails, followed by examples for calibration, parameter write, parameter read and target information parsing. Contact details for the company close the document. This manual is written in Chinese.
| Serial port settings | 115200 baud, 8 data bits, 1 stop bit, parity and flow control NONE |
|---|---|
| Supply current requirement (via USB-to-serial 3.3 V port) | Greater than 100 mA |
| Detection sensitivity range | 0x01–0x0F (default 0x0B) |
| GPIO multiplex mode default | 0x02 input mode, used for sleep wake-up |
| Distance calculation | Actual distance = byte3 * 0.05, unit: m |
| Environmental calibration time | 1.5 seconds |
| Wake-up command | AA AA D9 B2 68 2C 46 55 |
| Interface pins | VCC, GND, GPIO, RXD, TXD |
It can be woken by a wake command received over the serial port, or by applying a rising edge level change on the GPIO pin.
It runs once, acquires the parking space occupancy status and signal strength, sends this over the serial port, and then automatically returns to sleep.
It takes 1.5 seconds and stores the environmental variables so that the effects of the radome and the complex on-site environment are reduced.
The distance is the third byte of the target status message multiplied by 0.05, in meters.