This document is a technical service manual for the PLDC04318 product, which introduces the product's features and characteristics and maintenance methods.
This Technical Service Manual covers the maintenance and repair of the PLDC04318 unit. It includes detailed procedures for checking and replacing components such as the brush motor, carbon brushes, suction fan, solution pump, and various cables and brackets. The manual also addresses the replacement of idle wheels, carrying handles, and electrical components like the main switch and power board.
| Brush motor voltage | 36 V |
|---|---|
| Brush motor maximum power | 100 W |
| Brush rotation speed | 160 rpm |
| Motor protection rating | IP 44 |
| Carbon brush replacement interval | 400 - 500 hours |
| Carbon brush minimum length | 9 mm |
| Cap nut torque | 5.5 Nm |
The motor carbon brushes and rotor should be checked for wear every 400 - 500 operating hours.
The length of the carbon brush must be no less than 9 mm / 0.35 in.
Common causes include a flat battery, the main switch not being on, a broken main switch, or blown fuses.