This user manual is compiled by Nanjing Gnan Industrial Co., Ltd. This user manual provides detailed instructions on the fault troubleshooting methods of MCU-32 distributed modular automatic measurement unit, mainly including upper computer and MCU-32 connection abnormalities, upper computer shows that the collected data is 0, measurement module is not identified, main control display screen display abnormalities and other contents.
This manual provides troubleshooting steps for the MCU-32 distributed modular automatic measurement unit, covering issues like connection problems, data anomalies, module recognition failures, and display malfunctions. It also includes operational notes on power supply, communication methods, storage, and environmental protection.
The unit supports both wireless GPRS and RS485 communication, with detailed instructions for configuring each. Power options include solar, AC 220V, and battery, with specific requirements for each. Storage and environmental protection are also addressed, including flash memory management and lightning/waterproofing measures. This manual is written in Chinese.
| Battery Voltage (Main Unit) | 12.5V~14.5V |
|---|---|
| Battery Voltage (Single Point Module) | 3.8V~4.2V |
| Flash Memory | 4M 字节 |
The unit operates normally when the battery voltage is between 12.5V and 14.5V.
When powering multiple modules simultaneously, the current allocated to each module must be at least 300mA.
The module cannot work normally if the battery voltage drops below 3.6V.