JSY-MK-135D Micro Embedded Metering Module User Manual, mainly including product introduction, functional features, technical parameters, applications, MODBUS registers, MODBUS communication protocol, development tool instructions, product classification, and notes
This manual details the JSY-MK-135D micro embedded metering module, designed for monitoring electrical parameters in single-phase AC/DC systems. It includes technical specifications, MODBUS-RTU communication protocols, and installation instructions. The module supports voltage, current, power, and energy measurements with configurable UART communication and optional current transformers or manganese copper sensors.
The manual also covers safety precautions, wiring diagrams, and software tools for configuration and testing, including default settings and register addresses for data retrieval and system configuration. This manual is written in Chinese.
| Voltage Range | 0~100V or 220V selectable |
|---|---|
| Current Range | 0~16A (manganese copper direct insertion) or 20A/50A/100A (current transformer) |
| Measurement Accuracy | ≤1.0% for voltage, current, power; Class 1 for active energy |
| Operating Voltage | DC5V±5% |
| Operating Temperature | -20~+70℃ |
| Dimensions | 35×21×7mm |
| Data Update Rate | 1000ms |
| Default Baud Rate | 4800bps |
It uses the MODBUS-RTU protocol over UART for communication.
The default baud rate is 4800bps with data format 'n,8,1'.
The accuracy is ≤1.0% for voltage and current.
The operating voltage is DC5V±5%.