Tangshan Dafang Huizhong LCZ-803(A) Mine Explosion-Proof Digital Ultrasonic Flowmeter Installation Manual

LCZ-803(A) mine explosion-proof and intrinsically safe digital ultrasonic flowmeter is a meter for measuring liquid flow in circular pipes


Tangshan Dafang Huizhong LCZ-803(A) Mine Explosion-Proof Digital Ultrasonic Flowmeter Installation Manual - cover page
Brand
唐山大方汇中仪表有限公司
Category
Industrial Robot
Document type
Installation Guide
Language
Chinese
Pages
16
File format
PDF
File size
3.8 MB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
BA2D954FD7FA101CD79ED1F9520A41BC

About this manual

This document provides installation and operational instructions for the LCZ-803(A) mine explosion-proof digital ultrasonic flowmeter. It covers converter and sensor installation, wiring, display operation, and troubleshooting. The device is designed for use in explosive environments like coal mines, complying with GB3836 standards. It supports both insertion and clamp-on sensor types and offers multiple output options including 4-20mA, frequency, and RS485 communication.

The flowmeter measures liquids with suspended solids content under 10g/L and particle size under 1mm. It operates in temperatures from -10°C to +40°C and supports pipe diameters from DN50 to DN2000. The converter has IP54 protection, while sensors are IP68 rated. The device includes data storage for historical records and supports Modbus RTU and custom protocols. This manual is written in Chinese.

What's inside

  • Introduction
  • Converter Installation and Connection
  • Converter Display and Operation
  • Sensor Installation and Use
  • Cable Installation
  • Fault Diagnosis and Maintenance
  • RS485 Communication Protocol
  • Modbus Communication Protocol

Specifications

ModelLCZ-803(A)
BrandTangshan Dafang Huizhong Instrument Co., Ltd.
Measurement PrincipleVelocity difference method
Accuracy1.0 grade (0.5% repeatability) for insertion type, 1.5 grade (0.8% repeatability) for clamp-on type
Flow Velocity Range±0.3m/s to ±10m/s
Pipe Diameter RangeDN50mm to DN2000mm
Operating Temperature-10°C to +40°C
Power SupplyAC 127V (95V–140V), 50Hz or DC 24V
Converter Protection RatingIP54
Explosion-Proof TypeMine explosion-proof and intrinsically safe
Explosion-Proof MarkExd[ib]IMb
Communication Distance (RS485)Up to 1200m
Current Output Load≤500Ω
Data StorageCumulative flow, runtime, settings, 99 days of daily data, 36 months of monthly data, 12 years of annual data
Display4x8 character LCD with backlight
Medium CompatibilityWater, wastewater, industrial wastewater, etc. with suspended solids <10g/L and particle size <1mm
Pressure Rating (Insertion Sensor)2MPa (max 1MPa during installation)
Sensor Material1Cr18Ni9Ti (stainless steel)

Frequently asked questions

What is the operating temperature range for the LCZ-803(A)?

The operating temperature range is -10°C to +40°C.

What is the maximum communication distance for RS485?

The maximum RS485 communication distance is 1200 meters.

What is the explosion-proof type and mark of the LCZ-803(A)?

The explosion-proof type is mine explosion-proof and intrinsically safe, with mark Exd[ib]IMb.