This manual introduces the installation method of the electrolytic dehumidification element ROSAHL RS1 (welding type) / RS2 (plug-in terminal type).
This manual provides instructions for installing and operating ROSAHL RS1 and RS2 electric micro dehumidifiers. It details power requirements (DC 3V, non-reversible polarity), installation methods (M2 screws, sealing), and precautions (avoiding silicon sealants, volatile substances, and incorrect polarity). The manual also includes specifications for performance and dimensions, as well as recommended materials and prohibited substances to ensure optimal operation and longevity.
Users must follow all safety guidelines to prevent damage to the dehumidifier or stored items. The document emphasizes avoiding exposure to moisture, corrosive gases, and silicon-based materials, and provides specific installation and wiring instructions for both RS1 (welding type) and RS2 (plug-in terminal type) models. This manual is written in Chinese.
| Dehumidification Capacity | 210 mg/day (at 30°C, 60% humidity) |
|---|---|
| Operating Voltage | DC 3V |
| Power Consumption | 220 mW |
| Dimensions | H21 × W28 × D13.5 mm |
| Operating Temperature | -10°C to 50°C |
The dehumidifier requires DC 3V with correct polarity. Reversing polarity will reverse dehumidification and may damage components.
No, silicon-based sealants should not be used as they produce gases that degrade performance.
Use non-silicon sealants such as modified silicone (e.g., from Kosai Corporation).
Reversing polarity will reverse dehumidification and may cause chemical reactions that damage components.