HMLH-7Y SF6 Gas Recovery and Purification Device User Manual

HMLH-7Y SF6 gas recovery and purification device instruction manual, details the product's purpose, model, main technical parameters, working principle and structural features, pre-start work, operation instructions and precautions, maintenance and maintenance, common faults and elimination methods, after-sales service and other content.


HMLH-7Y SF6 Gas Recovery and Purification Device User Manual - cover page
Brand
武汉国电华美电气设备有限公司
Document type
User Manual
Language
Chinese
Pages
19
File format
PDF
File size
461 KB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
D628CDE747EE75716AD73B80ECA56A99

About this manual

This manual provides detailed instructions for operating the HMLH-7Y SF6 gas recovery and purification device, including setup, operation, maintenance, and troubleshooting. It covers technical specifications, working principles, safety precautions, and maintenance procedures for handling SF6 gas in electrical equipment.

The device features recovery, charging, purification, vacuum extraction, storage, and bottle-filling functions. It uses a refrigeration liquefaction method and includes safety controls such as pressure limiters and safety valves to ensure safe operation. This manual is written in Chinese.

What's inside

  • Introduction
  • Purpose and Model Description
  • Main Technical Parameters
  • Working Principle and Structural Features
  • Pre-Operation Preparation
  • Operation Instructions and Precautions
  • Maintenance and Care
  • Common Faults and Solutions
  • After-Sales Service

Specifications

Recovery Initial Pressure≤0.8MPa
Recovery Final Pressure≤50KPa
Recovery TimeLess than 2.5 hours for 1m³ SF6 from 0.8MPa to 50KPa
Charging TimeLess than 0.8 hours to charge 1m³ SF6 from 133Pa to 0.8MPa
Vacuum Limit≤10 Pa
Storage Capacity0.015m³
Noise Level≤75dB(A)
Operating Temperature-10°C to 40°C
Power SupplyThree-phase AC 50Hz 380V±10%
WeightApprox. 400 kg
Dimensions1360×800×1300 mm

Frequently asked questions

What is the maximum storage pressure for the device?

The maximum storage pressure is 3.8 MPa.

What is the noise level of the device?

The noise level is ≤75dB(A).

What is the operating temperature range?

The operating temperature range is -10°C to 40°C.