This manual introduces the features, usage instructions, installation instructions, technical data, etc. of the P45000 (P45*0*K2*, P45*1*K2*) high-voltage measuring transmitter.
This manual provides detailed instructions for installing, operating, and maintaining the Knick P45000 high voltage measuring transmitter. It includes safety guidelines, product specifications, connection details, and troubleshooting. The device is designed for voltage measurement in rail vehicles and industrial facilities, with features like electrical isolation and configurable output signals. Safety precautions are emphasized throughout to prevent electric shock and fire hazards.
The manual covers technical data, mounting options, wiring configurations, and maintenance procedures. It also includes information on SIL compliance for safety-critical applications and environmental conditions for proper operation. This manual is written in Chinese.
| Output Current | ±50 mA or 10–50 mA or 4–20 mA |
|---|---|
| Test Voltage | 10 kV AC or 20 kV AC |
| Operating Temperature | -40 to 85 °C |
| Power Supply | ±15/±24 V DC |
Output current options include ±50 mA (3-wire, bipolar), 10–50 mA (3-wire, unipolar), 4–20 mA (4-wire, unipolar), and ±20 mA (4-wire, bipolar).
Ensure the device is installed in a protected enclosure, follow EN 50343 for wiring, and use appropriate cable ratings. Avoid direct contact with exposed terminals and maintain safe distances from other equipment.
The operating temperature range is -40 to 85 °C.