Jiayu H100 Series AC Servo System User Manual

H100 series AC servo system user manual, introduces the product's hardware port, software function description, standard program function code table and other content.


Jiayu H100 Series AC Servo System User Manual - cover page
Brand
JIAYU
Category
Industrial Robot
Document type
User Manual
Language
Chinese
Pages
75
File format
PDF
File size
4.7 MB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
3BB45865CD88AB63C31B9DBEBBA6B086

About this manual

The Jiayu H100 Series AC Servo System is designed for motors up to 750W and supports position, speed, and torque control modes. It features RS485/CANopen bus communication and includes an oscilloscope function in the upper computer software for debugging and parameter modification.

The document provides detailed instructions on hardware specifications, installation requirements including EMC measures, standard wiring diagrams for various control modes, parameter configuration, and troubleshooting for common error codes such as undervoltage and overcurrent. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Model Definition
  • Application Functions
  • Hardware Specifications
  • Installation
  • Connection
  • Display and Operation
  • Parameter Settings
  • Function Usage
  • Modbus Communication

Specifications

Motor Power750W or less
Main Power InputSingle/Three-phase 220 VAC, ±10%, 50Hz
Control Power InputSingle-phase 220 VAC ±10%, 50Hz
Overload Capacity300% for ≤10s
Encoder FeedbackIncremental and Absolute
Pulse Input5V differential 0~500kHz; 24V single-ended 0~200kHz
Digital I/O9 inputs, 5 outputs
Analog Input2 channels, ±10VDC
Analog Output2 channels, ±10V
Communication ProtocolsModbus, CANopen
Operating Temperature-20~55℃

Frequently asked questions

What is the maximum power of the motor supported by this servo system?

The system is compatible with AC servo motors under 750W.

What control modes does the H100 Series support?

It supports position control, speed control, torque control, and single-axis control.

What communication protocols are available?

The system supports RS232/RS485 Modbus and CANopen protocols.

What are the causes and solutions for Error 15 (Undervoltage)?

Causes include low main power voltage or poor contact; solutions involve checking the power supply and restarting the unit.

Download PDF (4.7 MB)

More JIAYU Manuals


View all JIAYU manuals →