This is an installation manual that introduces how to install EV-QC45 standalone charger.
This manual provides detailed instructions for installing and operating the EFAPOWER EV‑QC45 standalone charging station, including safety, site preparation, and connection procedures.
It contains a table of contents covering product description, technical specifications, standards, parts presentation, installation steps, start‑up, user manual for connectors and operation, and maintenance guidelines.
| Nominal Input Voltage | 400 ± 10% V a.c. |
|---|---|
| Efficiency | > 93% |
| Power Factor | 0.98 |
| DC Output CHAdeMO Voltage | 50 to 500 V d.c. |
| DC Output CHAdeMO Current | 120 A d.c. |
| AC Output Voltage | 400 ± 10% V a.c. |
| AC Output Current | 63 A a.c. (or 32 A a.c.) |
| Dimensions | 600 x 600 x 1800 mm |
The maximum charging power is 50kW at peak and 45kW continuous.
Supported protocols include Web Services over IP, Router 3G (GSM or CDMA) OCPP, Efacec, and others.
Yes, the unit includes an emergency stop.