This document provides repair and maintenance instructions for Royal flushometer models, including repair parts and repair steps.
This document serves as a repair parts and maintenance guide for Royal flushometer models VBF-72-A1 and VBF-73-A2. It details the specific dimensions required for installation, including critical line distances and connection sizes, ensuring compliance with local codes.
| Vacuum Breaker Outlet Tube Size | 1-1/2" (38 mm) O.D. |
|---|---|
| Vacuum Breaker Outlet Tube Length (Model 3396075) | 8-1/2" (216 mm) |
| Vacuum Breaker Outlet Tube Length (Model 3396076) | 13" (330 mm) |
| Vacuum Breaker Outlet Tube Length (Model 3396077) | 21" (533 mm) |
| Vacuum Breaker Outlet Tube Length (Model 3396078) | 24" (610 mm) |
| Flexible Tubing Size | 3/8" (9 mm) x 12" (305 mm) |
Only mild soap and water should be used; abrasive or chemical cleaners may dull the luster and attack the chrome finish.
The standard repair kit is the V-651-A High Back Pressure Vacuum Breaker Repair Kit.
Some codes require a minimum distance of 6" (153 mm) between the critical line of the vacuum breaker and the trap primer outlet.