BVA Hydraulics Sequence Valve is used to sustain a load in the event of a loss of hydraulic system pressure.
This document provides the instruction manual for the BVA Hydraulics CVS3 Sequence Valve. The valve is designed to sustain a load in the event of a loss of hydraulic system pressure and is suitable for a wide variety of applications. It includes safety warnings regarding personal protective gear and proper connection procedures.
The manual details the installation and adjustment process, specifying how to connect the P (Pump) and CYL (Cylinder) ports and how to adjust the pressure setting using the adjustment valve. It also lists the service parts and their part numbers for authorized repairs.
The valve is used to sustain a load in the event of a loss of hydraulic system pressure.
Turn the adjustment valve clockwise to increase pressure and counterclockwise to reduce pressure.
No, alteration of the products is strictly prohibited, and the check valve should never be disassembled.