Provide Perma-Gard III's construction instructions.
This document outlines the requirements for installing the Neogard Perma-Gard III cold fluid-applied waterproofing system on new or existing concrete surfaces. It covers general project conditions, material specifications, and execution procedures to ensure a seamless waterproof membrane.
| Product Type | Coal-tar free, modified polyurethane liquid |
|---|---|
| Tensile Strength | 250 psi |
| Elongation | 500% |
| Permanent Set | 25% |
| Water Resistance | <3% |
| MVT at 60 mils | 0.60 English perms |
| Shore A Hardness | 30–40 |
| Adhesion | 200 psi |
The recommended material storage temperature is 75°F/23°C.
Materials should only be applied when the substrate temperature is above 40°F/4°C.