This is the user manual for Dickinson Marine's diesel heater.
This manual provides operating and installation instructions for Dickinson Marine natural draft diesel heaters, specifically the Lofoten, Newport, Alaska, and Antarctic models. It details the advantages of vaporizing oil burners, which transform oil into a vapor state for efficient and clean combustion. The document emphasizes the importance of proper ventilation, chimney design, and safety clearances to ensure correct operation and prevent hazards like downdrafts or explosions.
| Fuel Types | Diesel, Kerosene (K), Stove Oil (S) |
|---|---|
| Hot Water Coil Capacity (1 turn) | 5 -10 gallons |
| Hot Water Coil Capacity (2 turn) | 15-20 gallons |
| Oil Vaporization Temperature | 465 F |
| Fuel Pressure Limit | 4 psi |
| Fresh Air Inlet Diameter | 3" |
| Safety Clearance (Above) | 30" |
| Safety Clearance (In front) | 18" |
| Safety Clearance (Sides) | 12" |
| Safety Clearance (Below) | 6" |
The heater can be calibrated to run on diesel, kerosene (K), and stove oil (S).
The fresh air inlet must be at least 3 inches in diameter.
Fuel pressure must not exceed 4 psi, or a fuel pressure regulator must be used.
Oil vaporization is achieved when it reaches 465 F.