This document is the user manual for the AM series mixers
The INDCO AM Series Mixers are handheld air motor drive units designed for mixing applications. The manual covers essential safety precautions, such as never running the mixer without an impeller or in open air, and details the installation process involving the muffler and air supply line. It specifies that these mixers operate in a clockwise rotation when viewed from the top, though reversible models exist.
| Max Inlet Air Pressure | 100 PSIG |
|---|---|
| Max Ambient Temperature | 250°F |
| AM200-A Motor Power | ¾ HP |
| AM200-B Motor Power | 1½ HP |
The inlet air pressure should not exceed 100 PSIG.
Air drive motor mixers are designed to operate in a clockwise rotation when viewed from the top of the mixer looking downward.
A detergent SAE #10 automotive engine oil is recommended for lubrication.
Try flushing the motor with a recommended solvent like Gast Flushing solvent #AH255 or Loctite Safety Solvent.