Samson KS Series Liquid Ring Vacuum Pumps Instruction Manual

This manual describes the technical specifications, usage and installation of the Samson Liquid Ring Pumps KS series.


Samson KS Series Liquid Ring Vacuum Pumps Instruction Manual - cover page
Brand
Samson
Category
Other
Document type
User Manual
Language
English
Pages
52
File format
PDF
File size
7 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
E7253310E1062255EA349D67893F959F

About this manual

This instruction manual covers the Samson KS series of liquid ring vacuum pumps, specifically models KS500, KS510, KS625, KS725, KS910, and KS1025. Designed for applications in offshore, fish food, truck, and industrial sectors, the document provides comprehensive guidance on the pump's function, system layout, and design requirements.

What's inside

  • Introduction
  • Technical data
  • Design of the systems
  • Installation and start-up
  • Recommended service, maintenance and inspection intervals
  • Troubleshooting
  • Spare parts

Specifications

Ambient temperature, operation-20°C to 55°C
Intake temperature, suction side- to 120°C
Service liquid pipe connection, dimension¾”
Service liquid pipe connection, length6 m
Noise level80 dB
Revolutions1000 rpm to 1750 rpm
Service liquid flow3 litres/minute, self-regulating

Frequently asked questions

What is the maximum ambient temperature for operation?

The maximum ambient temperature for operation is 55°C.

What type of grease is recommended for automatic lubrication?

The recommended grease for automatic lubrication is SKF LAGD 125/WA2.

How long can the pump be stored without further action after operation?

The pump can be stored for 30 days without further action after operation.