This manual introduces the installation method of Harvia heater
This guide covers installation of Harvia 4.5kw, 6.0kw and 8.0kw heaters in Almost Heaven Saunas. It supplements the manufacturer’s manual and gives simple instructions for installing the heater, including electrical requirements and mounting steps.
Topics include breaker and wire sizing, GFCI restrictions, heater and temperature sensor placement, stone loading, timer operation, initial burn-in, testing, troubleshooting and high-limit control reset.
| Breaker (4.5kw/6.0kw) | 30-amp double pole |
|---|---|
| Breaker (8.0kw) | 40-amp double pole |
| Wire insulation | Copper wire with 90°C insulation |
| GFCI | Do not use |
| Mounting height | 7 inches from floor |
| Sensor distance | 12 inches from heater |
All wiring should be done by a licensed electrician.
No, do not use GFCI with this heater.
It heats for one hour and then automatically shuts off.
Vertically on the wall 12 inches to the right or left of the heater.