Harvia 4.5kw/6.0kw/8.0kw Heater Installation Guide

This manual introduces the installation method of Harvia heater


Harvia 4.5kw/6.0kw/8.0kw Heater Installation Guide - cover page
Brand
Harvia
Category
Heater
Document type
Installation Guide
Language
English
Pages
6
File format
PDF
File size
1.5 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
354052A4315B53442BD507E7B6590CC6

About this manual

This guide covers installation of Harvia 4.5kw, 6.0kw and 8.0kw heaters in Almost Heaven Saunas. It supplements the manufacturer’s manual and gives simple instructions for installing the heater, including electrical requirements and mounting steps.

Topics include breaker and wire sizing, GFCI restrictions, heater and temperature sensor placement, stone loading, timer operation, initial burn-in, testing, troubleshooting and high-limit control reset.

What's inside

  • Electrical requirements
  • Heater installation steps
  • Temperature sensor mounting
  • Stone loading
  • Timer operation
  • Testing the sauna heater
  • Troubleshooting
  • High limit control

Specifications

Breaker (4.5kw/6.0kw)30-amp double pole
Breaker (8.0kw)40-amp double pole
Wire insulationCopper wire with 90°C insulation
GFCIDo not use
Mounting height7 inches from floor
Sensor distance12 inches from heater

Frequently asked questions

Who should perform electrical work?

All wiring should be done by a licensed electrician.

Can a GFCI be used with the heater?

No, do not use GFCI with this heater.

How long does the heater run before shutting off?

It heats for one hour and then automatically shuts off.

Where should the temperature sensor housing be mounted?

Vertically on the wall 12 inches to the right or left of the heater.

Download PDF (1.5 MB)

More Harvia Manuals