This document describes the maintenance methods of the JV-KG series gear flow meter, including removing the flow meter, cleaning the flow meter, inspecting the flow meter, and reassembling the flow meter.
This two-page guide explains how to clean, inspect and repair AW JV-KG Series gear flow meters. It lists numbered steps for removing the sensor, separating the upper and lower housings, cleaning the gear assemblies and shafts, replacing o-rings, and reassembling the meter.
The guide gives bolt sizes and torque values for different meter sizes, notes handling of PTFE and FKM o-rings, and includes a cross-reference table for JV-XXKG Series spare parts. It was revised 07/2017 and lists the company address in Oak Creek, Wisconsin, and www.aw-lake.com.
| Bolt size for JV-30 and smaller meters | M6 |
|---|---|
| Bolt size for JV-60 meters | M10 |
| Bolt torque for 12, 20 and 30 size meters | 15 Nm |
| Bolt torque for 60 size meters | 30 Nm |
| O-rings per JVx-60KG meter | 2 |
| PTFE o-ring replacement | Always replace |
| FKM o-ring reuse | Can be reused if not damaged |
The bolts should be torqued to 30 Nm for 60 size meters.
Yes, FKM o-rings can be reused if they are not damaged.
JVx-60KG flow meters use 2 o-rings per meter.
Gently blow air through the meter so the gears spin; the spinning should be clearly audible.