This is the instruction manual for Højgaards medium pressure pump, which introduces information on use, maintenance, safety and warranty
The Højgaards Medium Pressure Pump user manual explains the pump's intended use for liquid fertilizers and manure, including sandy liquids and manure from stables where sawdust or shavings have been used. It covers the machine description, Højgaards data plate, safety, connection to a tractor, electrical connection, operation, inspection and maintenance, service and spare parts, disassembly, and warranty terms. The pump can be delivered for electric or tractor operation and may include mixing equipment, fittings, or a work platform as required.
Safety instructions state that cleaning, maintenance, or repair must not be carried out on the electric pump unless the main switch is off and locked, and the tractor must be switched off and disconnected before work on the tractor pump. Electrical installations and repairs must be carried out by an authorized electrician. The manual also lists maintenance intervals, oil types, and disposal steps.
| Rotor speed, electric operation | 1450 rpm |
|---|---|
| Rotor speed, PTO operation | 1000/2000 rpm |
| Electric motor power range | 5.5 kW to 30 kW |
| Gearbox power capacity | 75 kW |
| Shaft pipe oil | Q8 Goya 150 gear oil |
| Gearbox oil | Q8 T 55 85w-140 gear oil |
The rotor speed is 1450 rpm for electric operation.
A Q8 Goya 150 gear oil must be used.
Empty pump pipes and pump lines of manure before winter.
The warranty from Højgaards ApS will lapse.