About this manual

The Vermont Castings Jefferson Direct Vent/Natural Vent Room Heater, models 2820, 2822, 2823, 2825, 2827, and 2828, is a vented gas appliance listed to ANSI Z21.88b-2001 and CSA-2.33b-2001. It is shipped as a Direct Vent heater and may be converted to a Natural Vent unit with the Vermont Castings Z31D00 FSDHAG Draft Hood.

The manual covers installation requirements, locating and clearance, gas specifications, direct vent and natural vent assembly, gas supply connection, lighting and operating instructions, troubleshooting for the Honeywell #8420 gas control system, maintenance, wiring diagrams, replacement parts, and warranty.

What's inside

  • Installation Requirements
  • Clearance Requirements
  • Gas Specifications
  • Venting Requirements and Options - Direct Vent ONLY
  • Assembly Procedures
  • Connect Gas Supply Line
  • Lighting and Operating Instructions
  • Troubleshooting - Honeywell #8420 Gas Control System
  • Maintenance
  • Wiring Diagrams

Specifications

Gas typesNatural gas or propane only
Manifold pressure, natural gas3.5 inches w.c.
Manifold pressure, LP gas10 inches w.c.
Vent pipe size, Natural Vent4 inches
Certified models2820, 2822, 2823, 2825, 2827, 2828
Listing standardsANSI Z21.88b-2001 and CSA-2.33b-2001

Frequently asked questions

What should I do if I smell gas?

Do not try to light any appliance or touch any electric switch; call your gas supplier from a neighbor’s phone and follow the supplier’s instructions. If you cannot reach the supplier, call the fire department.

Can the Jefferson heater be converted to use a different gas?

No, it is only for use with the type of gas indicated on the rating plate and is not convertible unless a certified kit is used.

Where is the Jefferson heater approved to be installed?

It is approved for bedroom installations in the U.S. and Canada and may be installed in an aftermarket manufactured (mobile) home where not prohibited by local or state codes.

How often should the heater be inspected?

It should be inspected before use and at least annually by a qualified service agency.