This manual describes the features and usage methods of Jefferson® Direct Vent/Natural Vent Gas Heater.
The Vermont Castings Jefferson Direct Vent/Natural Vent Room Heater, models 2820, 2822, 2823, 2825, 2827, and 2828, is a vented gas appliance listed to ANSI Z21.88b-2001 and CSA-2.33b-2001. It is shipped as a Direct Vent heater and may be converted to a Natural Vent unit with the Vermont Castings Z31D00 FSDHAG Draft Hood.
The manual covers installation requirements, locating and clearance, gas specifications, direct vent and natural vent assembly, gas supply connection, lighting and operating instructions, troubleshooting for the Honeywell #8420 gas control system, maintenance, wiring diagrams, replacement parts, and warranty.
| Gas types | Natural gas or propane only |
|---|---|
| Manifold pressure, natural gas | 3.5 inches w.c. |
| Manifold pressure, LP gas | 10 inches w.c. |
| Vent pipe size, Natural Vent | 4 inches |
| Certified models | 2820, 2822, 2823, 2825, 2827, 2828 |
| Listing standards | ANSI Z21.88b-2001 and CSA-2.33b-2001 |
Do not try to light any appliance or touch any electric switch; call your gas supplier from a neighbor’s phone and follow the supplier’s instructions. If you cannot reach the supplier, call the fire department.
No, it is only for use with the type of gas indicated on the rating plate and is not convertible unless a certified kit is used.
It is approved for bedroom installations in the U.S. and Canada and may be installed in an aftermarket manufactured (mobile) home where not prohibited by local or state codes.
It should be inspected before use and at least annually by a qualified service agency.