This manual introduces the use and installation methods for the RSEF transmitter and the RSRDevice receiver of the RS series fleet safety stop and command system.
The RS series Fleet Safety Stop and Command System uses an RSEF transmitter to send safety and command signals via radio to one or more RSRDevice receivers installed on mobile equipment. The system provides emergency stop functionality meeting Performance Level PLe (Category 4) per EN ISO 13849-1 and SIL 3 per IEC 62061.
The manual details safety rules, component identification, operating principles, factory default settings, terminal block layouts, test wiring procedures, configuration via DIP switches and software, wiring guidelines, installation and commissioning instructions, optional radio components (RF switch, JUMP repeater, antennas), troubleshooting, maintenance, warranty, and applicable standards (FCC, IC, European directives).
| Radio channel number (default) | 64 (DIP switches 1 to 6 up) |
|---|---|
| Self-check of inputs upon auxiliary supply activation (default) | NO (DIP switch 7 down) |
| Transmitter restart mode (default) | Automatic (DIP switch 8 up) |
| Receiver safety delay (default) | 0s (configurable 0 to 10s) |
| Receiver passive stop time (default) | 1s (configurable 0.3 to 2s) |
| Power supply for test wiring | 24VDC ±20%, 500mA minimum |
| Emergency stop button type | NC double contact |
| SIM card identity code | Fixed unique hexadecimal code issued by JAY |
| SIM card serial number | Fixed unique number issued by JAY |
| Applicable radio bands | 434 MHz, 915 MHz, 920 MHz, 869 MHz |
| Safety standards compliance | EN ISO 13849-1:2015 PLe Cat.4, IEC 62061 SIL 3 |
The default radio channel is 64, set with DIP switches 1 to 6 in the up position.
The default safety delay is 0 seconds (configurable 0–10 s) and the default passive stop time is 1 second (configurable 0.3–2 s).
A stabilized 24 VDC power supply with ±20% tolerance and at least 500 mA capacity.
The system meets EN ISO 13849-1:2015 for Performance Level PLe (Category 4) and IEC 62061:2005+AC:2010+A1:2013+A2:2015 for SIL 3.