ITE MK-40-DS to MK-280-DS Vacuum Pump Instruction Manual

ITE Vacuum pumps Instruction manual


ITE MK-40-DS to MK-280-DS Vacuum Pump Instruction Manual - cover page
Brand
ITE
Category
Other
Document type
User Manual
Language
English
Pages
7
File format
PDF
File size
816 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
FB36D0FEBF8C040F2A166C6D6A8D353A

About this manual

This ITE instruction manual covers the MK-40-DS, MK-60-DS, MK-120-DS, MK-180-DS, MK-240-DS and MK-280-DS vacuum pumps. It gives safety guidelines and procedures for oil filling, oil changes and gas ballast operation.

The general operation section lists standard accessories including a solenoid valve, vacuum gauge, oil mist filter, non-return valve, dual voltage switch and 180 cm charging hose. The document also includes a parts section, model specifications and a one-year warranty statement.

What's inside

  • Safety guidelines
  • Oil filling
  • Oil change
  • Gas ballast
  • General operation
  • Parts
  • Specifications
  • Warranty

Specifications

Voltage220 V/50 Hz or 110 V/60 Hz
Ultimate vacuum15 micron (0.020 mBar) or 12 micron (0.016 mBar) depending on model
Motor0.19 kW to 0.56 kW depending on model
Oil capacity350 ml to 500 ml depending on model
Dimensions330 x 135 x 255 mm to 380 x 160 x 285 mm depending on model
Net weight9,80 kg to 16,50 kg depending on model

Frequently asked questions

What oil should be used in the pump?

Only ITE vacuum pump oil should be used. For continuous use on CFC and HCFC systems, ITE-205-P mineral vacuum pump oil is recommended.

When should I check the oil level?

Check the oil level only while the pump is running. When stopped, a correctly filled pump's oil level will fall below the 1/2 way level in the sight glass.

What does the gas ballast valve do?

It allows relatively dry air from the atmosphere to enter the pump and helps prevent contaminant vapors from condensing and mixing with the vacuum pump oil.

What is the minimum cold start temperature?

The minimum cold start temperature is 0°C. Below this temperature, an external heater should be used for trouble-free start-up.