This manual introduces how to use the S661 Rate Counter.
The S661 rate counter fits a standard 1/8 DIN panel cutout (1.77" high × 3.62" wide) and extends 3.24" behind the panel. It operates on 120 or 240 VAC, retains all programming and count data in nonvolatile EEPROM, and accepts count rates up to 30 kHz from various sensor types including quadrature, CMOS/TTL, and PNP/NPN devices. The unit is UL listed for indoor use up to 2000 m altitude, 0–40°C, installation category III, pollution degree 2.
The counter uses field‑replaceable slide‑in modules for input, excitation, power, and output (single or dual relay). Front‑panel programming with word prompts configures scaling, presets, output modes (latching, boundary, timed 0.01–599.99 s), and security features such as password lockout and reset disable. An optional 12 VDC (100 mA) excitation module can power external sensors.
| Panel cutout | 1.77" (45 mm) high × 3.62" (92 mm) wide |
|---|---|
| Depth behind panel | 3.24" (82 mm) |
| Power supply | 120 or 240 VAC, 50/60 Hz |
| Maximum count rate | 30 kHz |
| Sensor compatibility | Quadrature, CMOS/TTL, PNP/NPN |
| Output modes | Latching, boundary, timed (0.01–599.99 s) |
| Optional excitation output | 12 VDC, 100 mA |
| Memory retention | Nonvolatile EEPROM |
| Operating temperature | 0°C to 40°C |
| Altitude limit | 2000 m |
The S661 requires a standard 1/8 DIN cutout of 1.77" (45 mm) high by 3.62" (92 mm) wide.
The counter operates on either 120 VAC or 240 VAC, 50/60 Hz line power.
The S661 accepts count rates up to 30 kHz.
An active low signal (≤0.2 V) on the RESET and COMMON terminals performs a primary reset.