This Owners Guide describes the Culligan Medallist Plus Iron-OX5 water filter system, including installation and setup procedures, basic programming information, modes of operation, specifications and troubleshooting. It also covers bypassing the filter, care and cleaning, performance data, records and the Culligan limited warranty.

The filter uses oxidation to convert ferrous iron to ferric iron and remove it as a filterable particle, with periodic reconditioning through backwash, air draw and fast rinse cycles. Specifications list a 10" x 54" media tank, 500 gallon capacity, operating pressure of 20-60 psi and 28 volt electrical requirements.

What's inside

  • About This Manual
  • Thank You
  • Specifications
  • Application
  • Operation
  • Programming
  • Error Codes
  • When & How to Bypass Your Water Filter
  • Things to Check Before You Call For Service
  • Care and Cleaning of Your Water Filter

Specifications

Control Valve1" reinforced thermoplastic
Overall Conditioner Height67"
Media Tank Dimensions (D x H)10" x 54" tank
Capacity500 gallons
Max. Clear Water (Soluble) Iron5 ppm
Minimum Alkalinity100 ppm
pH for Iron Removal7.0 - 8.5
Service Flow @ Pressure Drop (Normal)4 gpm @ 5 psi
Service Flow @ Pressure Drop (Maximum)6 gpm @ 9 psi
Operating Pressure20-60 psi
Operating Temperature33-120° F (1-48° C)
Electrical Requirements28 Volts/50-60 Hz
Power Consumption, Continuous/Maximum3 Watts/21.6 Watts
Drain Flow5.5 gpm

Frequently asked questions

How much iron can the Iron-OX5 remove?

The Iron-OX5 is rated to remove up to 5 ppm of ferrous (clear water) iron.

What types of iron will the Iron-OX5 not remove?

Organic bound iron, bacterial iron and colloidal iron are not removed by the Iron-OX5 filter.

What are the reconditioning cycle times?

Backwash is 15 minutes, air draw is 40 minutes and fast rinse is 5 minutes.

Where are the serial numbers located?

The control valve serial number is on the back of the enclosure; the media tank serial number is on the top surface of the tank.