This is an operator's manual that introduces the use of the INVERTEC® V160 welding machine.
This is the operator's manual for the Lincoln Electric INVERTEC V160 welding machine, published by Lincoln Electric Italia S.r.l. (document W83CE172, Rev. 3, 01/2004). It opens with a declaration of conformity stating that the INVERTEC V160 conforms to directives 73/23/CEE, 93/68/CEE, 89/336/CEE and 92/31/CEE and was designed to norms EN 50199 and EN 60974-1.
The manual covers safety instructions, installation and use instructions including location, environment, mains supply and generator requirements, connection of welding cables and the MMA (stick electrode) and TIG (GTAW) welding processes. The text provided is partly in French; it refers to a technical specifications chapter for supply voltage, cable and fuse sizes.
| Protection rating | IP23S |
|---|---|
| Maximum ambient operating temperature | 40°C |
| Maximum slope for placement | 15° from horizontal |
| Supply voltage (V160) | 230 Vac ± 15% |
| Supply voltage (V160 2V) | 115 Vac or 230 Vac ± 10% |
| Generator frequency range | 50 to 60 Hz |
| Applicable norms | EN 50199, EN 60974-1 |
The V160 requires 230 Vac ± 15%; the V160 2V version accepts 115 Vac or 230 Vac ± 10%.
Yes, provided the auxiliary 230 Vac (or 115 V for the V160 2V) supply meets the stated requirements, including a frequency between 50 and 60 Hz and peak AC voltage below 205 V (115 V) or 410 V (230 V).
Welding cables are connected using Twist-Mate quick connectors by inserting the plug and turning it a quarter turn clockwise.