Anaheim Automation MDCKB1-240041 Brushless Controller User's Guide

This product is a 220VAC, 4A brushless controller


Anaheim Automation MDCKB1-240041 Brushless Controller User's Guide - cover page
Brand
Anaheim Automation
Category
Automation control Equipment
Document type
User Manual
Language
English
Pages
9
File format
PDF
File size
167 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
89B29E975B480382C001FDF4E411AF29

About this manual

This User's Guide from Anaheim Automation covers the MDCKB1-240041 220VAC, 4A Brushless Controller, a DC brushless motor driver rated for up to 4A peak current and 340V. It explains driver features, general operation, fault protection, and ordering information for the MDCKB1-240041 and the open-loop MDCKB1-240041-01 variant.

The document provides specifications for control inputs, power requirements, and operating temperature, along with commutation sequences and motor connection instructions. It also covers closed-loop compensation, speed adjustment using potentiometers R11, R17, and R25, run/stop and direction control, motor enable, and heating considerations for the heat sink.

What's inside

  • Driver Features
  • General Description
  • Fault Protection
  • Ordering Information
  • Specifications
  • Control Inputs
  • Motor Connection
  • Closed Loop Compensation and Rated Motor Speed Range Adjustment
  • Speed Adjust Setting
  • Heating Considerations

Specifications

Maximum Current Limit1.0-4.0 Amps (peak)
Input Voltage200-240 VAC
Dimensions4.3”x4.09”x1.77”
Output Current RatingAdjustable 1.0 - 4.0 amperes per phase peak
Power Requirements200VAC (min) - 240VAC (max)
Operating Temperature0° - 70°C
Hall Sensor Power Output6.25V @ 30mA maximum

Frequently asked questions

What is the maximum peak current of the MDCKB1-240041 driver?

The maximum current limit is adjustable from 1.0 to 4.0 Amps peak.

What AC input voltage does the driver require?

It requires 200-240 VAC input power.

Does the MDCKB1-240041 driver have an internal fuse?

No, the driver does not have an internal fuse, so an external fuse is needed.

Download PDF (167 KB)