This is an operator manual that mainly introduces the operation methods of the steam generator, including installation, use and maintenance.
This operator manual covers the Groen HY-12GF and HY-24GF HyCapacity HyPerSteam atmospheric convection steamers. The HY-12GF has one cavity and one steam generator; the HY-24GF has two cavities and two generators. Each cavity uses blowers to circulate steam, and the dual-position pan rack can hold either 12 x 20 inch steamer pans or 18 x 26 inch bake pans.
The manual includes safety warnings, water conditioning requirements, installation and start-up instructions, operating instructions, cleaning, maintenance, troubleshooting, parts list, and schematics. It states that water to the steam generator should have between 10 and 30 ppm total dissolved solids and a pH of 7.0 or higher.
| Voltage | 108-126 V, 1 phase, 50/60 Hz |
|---|---|
| Current per cavity | 2.5 A ± 10% |
| Gas connection | ¾ inch NPT |
| Cold water supply connection | ¾ inch hose |
| Drain connection | 2½ inch hose connection |
| Steam generator water total dissolved solids | 10-30 ppm |
| Steam generator water pH | 7.0 or higher |
The manual states water should have between 10 and 30 ppm total dissolved solids.
They require 108-126 V, single phase, 50/60 Hz.
The rack can be set for 12 x 20 inch steamer pans or 18 x 26 inch bake pans.
The gas connection is ¾ inch NPT.