Groen HY-12GF HY-24GF HyCapacity HyPerSteam Self-Contained Gas Heated Convection Steamer Operator Manual

This is an operator manual that mainly introduces the operation methods of the steam generator, including installation, use and maintenance.


Groen HY-12GF HY-24GF HyCapacity HyPerSteam Self-Contained Gas Heated Convection Steamer Operator Manual - cover page
Brand
Groen
Category
Food Machinery
Document type
User Manual
Language
English
Pages
23
File format
PDF
File size
504 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
68A349859DF44867A0CCA5D4A77F407B

About this manual

This operator manual covers the Groen HY-12GF and HY-24GF HyCapacity HyPerSteam atmospheric convection steamers. The HY-12GF has one cavity and one steam generator; the HY-24GF has two cavities and two generators. Each cavity uses blowers to circulate steam, and the dual-position pan rack can hold either 12 x 20 inch steamer pans or 18 x 26 inch bake pans.

The manual includes safety warnings, water conditioning requirements, installation and start-up instructions, operating instructions, cleaning, maintenance, troubleshooting, parts list, and schematics. It states that water to the steam generator should have between 10 and 30 ppm total dissolved solids and a pH of 7.0 or higher.

What's inside

  • Important Operator Safety Warnings
  • Equipment Description
  • Water Conditioning
  • Installation and Start-Up Instructions
  • Operating Instructions
  • Cleaning
  • Maintenance
  • Troubleshooting
  • Parts List
  • Schematics

Specifications

Voltage108-126 V, 1 phase, 50/60 Hz
Current per cavity2.5 A ± 10%
Gas connection¾ inch NPT
Cold water supply connection¾ inch hose
Drain connection2½ inch hose connection
Steam generator water total dissolved solids10-30 ppm
Steam generator water pH7.0 or higher

Frequently asked questions

What total dissolved solids level should the steam generator water have?

The manual states water should have between 10 and 30 ppm total dissolved solids.

What voltage and phase do the steamers require?

They require 108-126 V, single phase, 50/60 Hz.

What pan sizes can the dual-position pan rack hold?

The rack can be set for 12 x 20 inch steamer pans or 18 x 26 inch bake pans.

What gas connection is specified?

The gas connection is ¾ inch NPT.