This is the owner's manual and instructions for the lbwhite company's #1 / #2 fuel oil foreman ductable indirect-fired oil heater
The L.B. White Foreman is a ductable indirect-fired oil heater available in CI230, CI500 and CI750 models with maximum inputs of 230,000, 500,000 and 750,000 Btuh. It uses #1 or #2 fuel oil and is listed for temporary heating of buildings under construction, alteration or repair. The manual covers specifications, safety precautions, moving, installation, start-up, shutdown, cleaning, maintenance, service, troubleshooting, wiring and parts.
The heater uses a burner assembly with an electronic igniter, solenoid valves and a burner head with orifice. Combustion by-products go up a vent stack to the outside, and a blower moves air over the heat exchanger to deliver warm, dry air. The manual also gives clearances, fuel storage distances, electrical supply details and a warranty policy.
| Fuel Type | #1 or #2 fuel oil |
|---|---|
| Maximum Input (CI230) | 230,000 Btuh / 67.4 kW |
| Maximum Input (CI500) | 500,000 Btuh / 146.54 kW |
| Maximum Input (CI750) | 750,000 Btuh / 219.8 kW |
| Air Flow | 1,600 / 3,457 / 4,280 CFM (CI230 / CI500 / CI750) |
| Electrical Supply | 120/60/1 or 240/60/1 V/Hz/Phase |
| Fuel Tank Capacity | 42 / 159 or 61 / 231 gal. / liter |
The specifications list #1 or #2 fuel oil.
It is listed for temporary heating of buildings under construction, alteration, or repair.
No. The manual states it is not for home or recreational vehicle use.