This manual provides all of the information necessary for the safe and proper installation, operation and maintenance of ECONO LIFT TILT TABLES.
The manual covers ECONO lift tilt tables, high point tilters and drive-on tilts. It describes safety warnings, inspection on receipt, installation of stationary tilt tables, electrical supply recommendations, hydraulic fluid requirements and testing procedures. A nameplate on each table gives load capacity ratings, serial number, drawing number and date of manufacturing.
Operation is controlled with up and down buttons; the motor drives a positive displacement pump that raises the platform, and a solenoid valve allows oil to return so the table lowers. The manual lists monthly routine maintenance checks and troubleshooting steps for problems such as the table not moving, not going down, descending by itself or stalling before full dump position.
| Motor 1 HP, 120 V, 1 phase fuse and breaker | 30 Amp fuse, 25 Amp breaker |
|---|---|
| Motor 1 HP, 240 V, 1 phase fuse and breaker | 25 Amp fuse, 20 Amp breaker |
| Motor 1.5 HP, 208-240 V, 3 phase fuse and breaker | 15 Amp fuse, 10 Amp breaker |
| Motor 1.5 HP, 460 V, 3 phase fuse and breaker | 7.5 Amp fuse, 5 Amp breaker |
| Hydraulic fluid | CSR Dextron IIC automatic transmission fluid or equivalent |
| Velocity fuse lock-up flow | 5 Gal/Min |
| Relief valve | Factory preset for maximum safe capacity; see nameplate |
Use CSR Dextron IIC automatic transmission fluid, or an equivalent fluid.
All routine maintenance should be performed monthly.
The velocity fuse may be locked up; close the flow control valve a few turns clockwise, press the up button for a few seconds and try again.
No, it should be picked up by the base frame only, using a strap or sling.