Econolift ECONO Tilt Tables, High Point Tilters and Drive On Tilts Operation and Maintenance Manual

This manual provides all of the information necessary for the safe and proper installation, operation and maintenance of ECONO LIFT TILT TABLES.


Econolift ECONO Tilt Tables, High Point Tilters and Drive On Tilts Operation and Maintenance Manual - cover page
Brand
Econo Lift
Category
Other
Document type
Service Manual
Language
English
Pages
7
File format
PDF
File size
332 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
51D6908C68B88A51C171E68406BCCE06

About this manual

The manual covers ECONO lift tilt tables, high point tilters and drive-on tilts. It describes safety warnings, inspection on receipt, installation of stationary tilt tables, electrical supply recommendations, hydraulic fluid requirements and testing procedures. A nameplate on each table gives load capacity ratings, serial number, drawing number and date of manufacturing.

Operation is controlled with up and down buttons; the motor drives a positive displacement pump that raises the platform, and a solenoid valve allows oil to return so the table lowers. The manual lists monthly routine maintenance checks and troubleshooting steps for problems such as the table not moving, not going down, descending by itself or stalling before full dump position.

What's inside

  • Introduction
  • Safety
  • Installation
  • Electrical
  • Hydraulics
  • Testing
  • Operation
  • Operating Procedure
  • Routine Maintenance
  • Trouble Shooting Maintenance

Specifications

Motor 1 HP, 120 V, 1 phase fuse and breaker30 Amp fuse, 25 Amp breaker
Motor 1 HP, 240 V, 1 phase fuse and breaker25 Amp fuse, 20 Amp breaker
Motor 1.5 HP, 208-240 V, 3 phase fuse and breaker15 Amp fuse, 10 Amp breaker
Motor 1.5 HP, 460 V, 3 phase fuse and breaker7.5 Amp fuse, 5 Amp breaker
Hydraulic fluidCSR Dextron IIC automatic transmission fluid or equivalent
Velocity fuse lock-up flow5 Gal/Min
Relief valveFactory preset for maximum safe capacity; see nameplate

Frequently asked questions

What hydraulic fluid should be used in the tilt table?

Use CSR Dextron IIC automatic transmission fluid, or an equivalent fluid.

How often should routine maintenance be performed?

All routine maintenance should be performed monthly.

What should I check if the tilt table will not go down?

The velocity fuse may be locked up; close the flow control valve a few turns clockwise, press the up button for a few seconds and try again.

Can the tilt table be moved by lifting the platform?

No, it should be picked up by the base frame only, using a strap or sling.

Download PDF (332 KB)