About this manual

This maintenance manual covers the Duke TSC Proofer Oven with Touch Screen Controls, models TSC-6/18M and TSC-3/9M. It is marked for maintenance by qualified, trained personnel only and includes safety instructions, start-up, programming controls, care and cleaning, door adjustments and gasket maintenance, troubleshooting, parts list and illustrations, and wiring diagrams.

The manual also covers water supply and backflow prevention, including installing and flushing the water filter and the required supply pressure. Cleaning instructions include the Opti-Mist proofer spray nozzle and weekly cleaning steps.

What's inside

  • Important Safety Instructions
  • Oven/Proofer Start-Up
  • Programming Controls
  • Care and Cleaning
  • Door Adjustments and Gasket Maintenance
  • Troubleshooting
  • Parts List and Illustrations
  • Wiring Diagram

Specifications

Minimum water supply pressure40 PSIG (275 KPa)
Maximum water supply pressure65 PSIG (448 KPa)
Minimum top clearance to ceiling6 in. (152.4 mm)

Frequently asked questions

What water supply pressure is required for the Duke TSC Proofer Oven?

Water supply pressure must be a minimum of 40 PSIG (275 KPa) and a maximum of 65 PSIG (448 KPa) at the water line inlet.

How often should the water filter cartridge be replaced?

The water filter cartridge should be replaced at least once per year.

How long should the oven and proofer pre-heat before operation?

Allow the oven and proofer to pre-heat for at least 30 minutes.

What should be done if mineral deposits cannot be removed from the Opti-Mist nozzle?

Replace the nozzle assembly if hard-water mineral deposits cannot be removed.