This document is the user manual for the 2020 and 2220 thermostat models.
The Braeburn 2020 and 2220 are programmable thermostats. The manual states the thermostat requires 24 Volt AC power or two properly installed AA alkaline batteries and is compatible with single-stage heat/cool conventional and heat pump systems; the 2220 also supports conventional systems up to 2 heat/2 cool and single-compressor heat pump systems with an auxiliary heat stage.
The guide covers specifications, thermostat parts, installation and wiring, system testing, user options, program schedule settings, operation, additional features and thermostat maintenance. It notes that installation is for experienced service technicians only and warns to turn off power to the heating or cooling equipment before installation.
| Electrical Rating | 24 Volt AC |
|---|---|
| Maximum Load | 1 amp per terminal |
| AC Power | 18 – 30 Volts AC |
| DC Power | 3.0 Volt DC |
| Control Range | 45° – 90° F (7° – 32° C) |
| Temperature Accuracy | +/- 1° F (+/- .5° C) |
| 2020 Terminations | Rc, Rh, O, B, Y1, W1, G, C |
It requires 24 Volt AC power or two properly installed AA alkaline batteries for proper operation.
It is compatible with single-stage heat/cool conventional and heat pump systems; the 2220 also supports conventional systems up to 2 heat/2 cool and single-compressor heat pumps with auxiliary heat.
The control range is 45° to 90°F (7° to 32°C).
Hold down the RETURN button for approximately 3 seconds until the screen changes to the first User Option.