This is a manual of Builder Series Mercury-Free Mechanical Thermostats
This manual covers the Builder Series Mercury-Free Mechanical Thermostats with the Megaswitch magnetic switch technology. It is for low voltage, single stage gas, oil or electric heating or cooling systems, and it includes models 500 and 505.
The manual has safety information, specifications, installation steps, using instructions, troubleshooting, wiring diagrams, and a one year limited warranty. Model 500 can be used with single stage heat pumps, and models 500 and 505 can also be used on 250 to 750 millivolt heat only systems. Do not use the thermostat on applications with voltages above 30 volts AC.
| Electrical Rating | 24 Volt AC (18-30 Volt AC), 250 – 750 millivolts |
|---|---|
| Heat Anticipation | 0.15 to 1.2 amps |
| Temperature Range | 50° - 90° F (10° - 32° C) |
It is designed for use with 24 Volt AC low voltage single stage systems and can also be used on 250 to 750 millivolt heating only systems. Do not use it on applications with voltages above 30 Volts AC.
Always turn off power to the air conditioning or heating system prior to installing, removing cleaning or servicing thermostat.
Do not select COOL mode of operation if the outside temperature is below 50° F (10° C).