Builder 500 / 505 Series Mercury-Free Mechanical Thermostats User Manual

This is a manual of Builder Series Mercury-Free Mechanical Thermostats


Builder 500 / 505 Series Mercury-Free Mechanical Thermostats User Manual - cover page
Brand
Builder
Category
Air conditioner
Document type
User Manual
Language
English
Pages
3
File format
PDF
File size
542 KB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
85630DB822AF67AF900C7846B11AE709

About this manual

This manual covers the Builder Series Mercury-Free Mechanical Thermostats with the Megaswitch magnetic switch technology. It is for low voltage, single stage gas, oil or electric heating or cooling systems, and it includes models 500 and 505.

The manual has safety information, specifications, installation steps, using instructions, troubleshooting, wiring diagrams, and a one year limited warranty. Model 500 can be used with single stage heat pumps, and models 500 and 505 can also be used on 250 to 750 millivolt heat only systems. Do not use the thermostat on applications with voltages above 30 volts AC.

What's inside

  • Models
  • Safety Information
  • Specifications
  • Installation
  • Testing Your New Thermostat
  • Troubleshooting
  • Using Your New Thermostat
  • Wiring Diagrams
  • One Year Limited Warranty

Specifications

Electrical Rating24 Volt AC (18-30 Volt AC), 250 – 750 millivolts
Heat Anticipation0.15 to 1.2 amps
Temperature Range50° - 90° F (10° - 32° C)

Frequently asked questions

What voltage can the Builder Mercury-Free thermostat be used with?

It is designed for use with 24 Volt AC low voltage single stage systems and can also be used on 250 to 750 millivolt heating only systems. Do not use it on applications with voltages above 30 Volts AC.

When should you turn off power before servicing the thermostat?

Always turn off power to the air conditioning or heating system prior to installing, removing cleaning or servicing thermostat.

When should you not select COOL mode?

Do not select COOL mode of operation if the outside temperature is below 50° F (10° C).