This manual introduces the basic use and precautions of the GYSMI 190 welding machine.
This manual provides instructions for operating the GYSMI 190 inverter welder, including setup, welding procedures, safety precautions, and maintenance. It details electrical connections, current settings, and safety features like over-voltage protection and thermal shutdown. The device is designed for MMA and TIG scratch welding with various electrode types and includes safety warnings for electrical shock, arc radiation, and environmental hazards.
The manual also covers troubleshooting common issues, such as no current output or cooling time delays, and advises on proper storage, cleaning, and protective gear to ensure safe operation.
| Voltage | 230V (50-60 Hz) |
|---|---|
| Current | Max 32.8A |
| Duty Cycle | 75% and 100% |
| Protection Rating | IP23 |
| Standards | EN 60974-1 |
The maximum current is 32.8A, with effective current at 28A.
It supports MMA (manual arc) and TIG scratch welding with electrodes for rutile, basic, stainless steel, cast iron, and aluminum.
Check if the cooling time has passed and verify that the voltage is within 30V ±15%. If not, consult the manufacturer for assistance.