This user guide covers the use of the Mecmesin Shotcrete Penetrometer, as supplied for the measurement of the resistance force of young sprayed concrete. It also covers the procedure for the subsequent calculation of the compressive strength of the concrete according to EN ISO 14488-2 (Method A) and similar industry test methods.
This user guide covers the use of the Mecmesin Shotcrete Penetrometer (Part No. 431-447-01) for measuring the resistance force of young sprayed concrete. The device is designed to calculate compressive strength according to EN ISO 14488-2 (Method A) and similar industry test methods.
The document outlines the principle of operation, which involves using a penetration needle of specified dimensions to measure the force required to push into the concrete to a depth of 15 mm. It provides instructions on preparing the apparatus, conducting tests at multiple sample locations, and using conversion curves to derive the estimated compressive strength from the force readings.
| Accuracy | 10 N |
|---|---|
| Needle diameter | 3 mm |
| Tip taper angle | 60° |
| Penetration depth | 15 mm |
| Concrete thickness requirement | 100 mm |
It is used for testing to EN ISO 14488-2 (Method A) and similar industry test methods.
The strength development of young sprayed concrete is assessed in the ranges of 0.2 MPa to 1.2 MPa.
The unit includes 15 needles which fit into the adaptor.