Camfil APC Farr Gold Series GS1 Mini Dust Collector Instruction Manual

This manual introduces the use of Farr Gold Series® Dust Collector, including installation, use and maintenance.


Camfil APC Farr Gold Series GS1 Mini Dust Collector Instruction Manual - cover page
Brand
Camfil APC
Category
Other
Document type
User Manual
Language
English
Pages
19
File format
PDF
File size
4.2 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
69A5E93F030CDBDC288A9F9DB7652901

About this manual

This manual provides instructions for the Camfil APC Farr Gold Series GS1 Mini dust collector, designed for collecting and filtering fume and non-explosive dry dust. It covers intended use, safety precautions, and specific conditions for safe operation, such as removing castors and bolting the unit to the floor before use.

The document details installation procedures, including foundation requirements and field utility connections. It also provides step-by-step instructions for filter installation and replacement, along with preventive maintenance schedules for filter elements, the hopper, valves, and the control system. Troubleshooting guidance is included to assist with common operational issues.

What's inside

  • Definitions
  • Intended Use
  • Safety Precautions
  • Receiving Your Equipment
  • Installation of the Equipment
  • Field Utility Connections
  • Filter Installation / Replacement
  • System Operation
  • Preventive Maintenance
  • Troubleshooting

Specifications

Filtration Efficiency99.99% on 0.5 micron and larger particles by weight
Operating AirflowMax. 850 m3/h
Filter Area120 m2 (1 x 30 m2)
Filter MaterialCellulose / Polyester HemiPleat Standard Green
Operating Temperature- 20 ºC to + 40 ºC
Voltage Supply230/400 V 3p, 50 Hz
Power1.1 KW/DOL
Weight262 Kg
Dimensions569 x 696 x 2146 mm (W x L x H)

Frequently asked questions

What is the intended use of the Farr Gold Series dust collector?

It is designed for collecting and filtering fume and non-explosive dry dust.

What safety precaution must be taken before operating the unit?

The castors for transportation must be removed and the dust collector must be bolted to the floor.

Who should perform the assembly, electrical installation, and troubleshooting?

These tasks should be performed by qualified personnel.