This manual introduces the use of Farr Gold Series® Dust Collector, including installation, use and maintenance.
This manual provides instructions for the Camfil APC Farr Gold Series GS1 Mini dust collector, designed for collecting and filtering fume and non-explosive dry dust. It covers intended use, safety precautions, and specific conditions for safe operation, such as removing castors and bolting the unit to the floor before use.
The document details installation procedures, including foundation requirements and field utility connections. It also provides step-by-step instructions for filter installation and replacement, along with preventive maintenance schedules for filter elements, the hopper, valves, and the control system. Troubleshooting guidance is included to assist with common operational issues.
| Filtration Efficiency | 99.99% on 0.5 micron and larger particles by weight |
|---|---|
| Operating Airflow | Max. 850 m3/h |
| Filter Area | 120 m2 (1 x 30 m2) |
| Filter Material | Cellulose / Polyester HemiPleat Standard Green |
| Operating Temperature | - 20 ºC to + 40 ºC |
| Voltage Supply | 230/400 V 3p, 50 Hz |
| Power | 1.1 KW/DOL |
| Weight | 262 Kg |
| Dimensions | 569 x 696 x 2146 mm (W x L x H) |
It is designed for collecting and filtering fume and non-explosive dry dust.
The castors for transportation must be removed and the dust collector must be bolted to the floor.
These tasks should be performed by qualified personnel.