This document is the Goldline reverse osmosis drinking water system installation and service guide, which introduces the product's use methods, precautions and maintenance
This guide provides step-by-step instructions for installing the GOLDLINE-50-NA reverse osmosis system, including tool requirements, filter and membrane replacement schedules, and plumbing connections. It also covers safety precautions, such as avoiding hot water lines and ensuring proper water pressure. Maintenance is emphasized, with filters to be changed every six months and membrane every 2-5 years, depending on water quality.
The system is certified for nitrate/nitrite reduction and must be used with bacteriologically safe water. Installation requires drilling holes, connecting tubing with compression fittings, and ensuring proper faucet and tank placement. Optional ice maker hook-up is detailed, with tubing size recommendations based on distance from the unit.
| Model | GOLDLINE-50-NA |
|---|---|
| Efficiency Rate | 21.9 % |
| Recovery Rate | 39 % |
| Daily Production Rate | 13.4 gpd |
| Nitrate Limit | 27 mg/L |
| Nitrite Limit | 3 mg/L |
| Minimum System Pressure | 30 psi |
| Maximum System Pressure | 100 psi |
| Temperature Range | 4º / 38ºC (40º / 100º F) |
| Maximum TDS Level | 1800 mg/L |
| Turbidity Limit | < 1.0 NTU |
Filters should be changed every six months, depending on feed water quality.
The system is designed for influent concentrations of no more than 27 mg/L nitrate.
Required tools include a variable speed drill, Teflon tape, Relton drill, small knife, 1" hole saw, and Phillips screwdriver.