About this manual

The Nordco OnePass G3 is a modular ultrasonic rail test system designed for assessing rail integrity with a single pass. It features a rugged Windows tablet, a specialized wheel probe with 11 transducers, and smart couplant delivery. The system runs on Nordco's Rail Truck software and supports data sharing via cloud services and Microsoft Office tools.

The document provides detailed instructions on safety guidelines, installation, and battery management. It covers daily, monthly, and post-shift maintenance procedures, as well as troubleshooting steps for common issues. The manual also lists spare parts and accessories available for the system.

What's inside

  • Introduction
  • Safety Advice
  • Installation & Setup
  • Operation
  • Preventive Maintenance
  • Troubleshooting
  • Customer Service & Spare Parts

Specifications

Product DesignationAssembly number 1103100
Operating SystemWindows 7
Battery Type (Standard)24V Li-Mn
Battery Type (Air Transport)Ni-Mh
Charging Time (Li-Mn)2-3 hours
Charging Time (Ni-Mh)5-6 hours
Transducer Count11

Frequently asked questions

What is the assembly number for the OnePass G3?

The assembly number is 1103100, located on the serial number label next to the couplant tank.

How long does it take to fully charge the standard Li-Mn battery?

It takes approximately 2 to 3 hours to fully charge the standard Li-Mn battery.

Can Li-Mn and Ni-Mh batteries be interchanged in the field?

No, Li-Mn and Ni-Mh batteries are not interchangeable in the field as the power supply electronics need factory calibration for the chosen battery option.

What safety glasses are required for maintenance?

Safety glasses must be worn at all times when performing maintenance tasks on the OnePass system.