This manual is intended for the installation, operation and maintenance of all IKON commercial gas ranges
This document serves as the installation, operation, and maintenance manual for IKON gas restaurant ranges. It provides detailed instructions for uncrating, location selection, and assembly, including the installation of backsplashes and casters. The manual specifies safety warnings regarding gas installation and clearance requirements from combustible materials.
| Top burner input (Natural Gas) | 30,000 BTU/hr |
|---|---|
| Top burner input (LP) | 27,000 BTU/hr |
| Oven input (Natural Gas) | 33,000 BTU/hr |
| Oven input (LP) | 28,000 BTU/hr |
| Top griddle input (Natural Gas) | 30,000 BTU/hr |
| Top griddle input (LP) | 27,000 BTU/hr |
| Top thermostat griddle input (Natural Gas) | 30,000 BTU/hr |
| Top thermostat griddle input (LP) | 27,000 BTU/hr |
| Top char broiler input (Natural Gas) | 35,000 BTU/hr |
| Top char broiler input (LP) | 35,000 BTU/hr |
Ranges must be installed in accordance with State and local codes, National Fuel Gas Code ANSI/Z223.1, and in Canada, CSA B149.1 and CSA C22.1.
A minimum front clearance of 40 inches (1016 mm) is required for the range.
No, gas conversion must be performed by a certified/licensed technician and not attempted by yourself.
The labor warranty covers standard straight time labor charges for repairs within one year after the original date of installation.