About this manual

This manual explains how to use the ISCO Hydraulic Butt Fusion Machine to join polyethylene pipes. It covers cleaning, clamping, facing, heating, joining, and holding steps. The document also details how to adjust hydraulic pressures, calculate fusion pressure, and handle pipes with different wall thicknesses. Safety warnings are included for proper operation.

The machine includes a manifold block with valves for facing, heating, and fusion pressure. Users must set pressures using a calculator or reference charts, and account for drag pressure when moving pipes. The manual provides formulas and tables for calculating fusion pressure based on pipe dimensions and machine model.

What's inside

  • Cleaning Pipe Ends
  • Clamping
  • Facing Pipe Ends
  • Aligning Pipes
  • Heating Pipes
  • Joining Pipes
  • Holding the Joint
  • Adjusting Hydraulic Pressure
  • Calculating Fusion Pressure
  • Handling Different Wall Thicknesses

Specifications

Recommended Interfacial Pressure (IFP)5.2 Bar (75 psi)
Heater Surface TemperatureMinimum 205°C (400°F), Optimum 218°C (425°F), Maximum 230°C (450°F)

Frequently asked questions

What is the recommended interfacial pressure for fusion?

The optimum interfacial pressure is 5.2 Bar (75 psi).

What is the heater surface temperature range?

The heater surface temperature should be between 205°C (400°F) minimum and 230°C (450°F) maximum.

How do you calculate fusion pressure?

Use the formula: Gauge Pressure = (OD - t) x t x π x IFP / TEPA + Drag Pressure.