This document is the installation and maintenance manual for the Fife-200 Web Guiding System. It introduces the methods of installing, maintaining and repairing the product.
The Fife-200 Web Guiding System is a small web guide and controller consisting of an offset pivot guide, a controller capable of controlling four guides and sensors, and an operator interface. It is designed for continuous use and controls web position by monitoring the web with a sensor and driving an actuator connected to the guide assembly. The system features an IP40 ingress protection rating and is available in various roll face and guide spans.
| Ingress Protection Rating | IP40 |
|---|---|
| Controller Sensor Inputs | one sensor input per guide |
| Controller Parallel Inputs | three parallel inputs per guide |
| Controller Parallel Outputs | one parallel output per guide |
| Operating Voltage | 24 VDC +10%/ -6% |
| Wire Size | 0.82 mm^2 (18 AWG) |
| Wire Temperature Rating | at least 80 ⁰C |
The system operates on a 24 VDC power supply with a tolerance of +10%/-6%.
The recommended wire size is 0.82 mm^2, which corresponds to 18 AWG.
No, the Fife-200 Web Guiding System is not intended for use in Ex-areas or intrinsically safe areas.