Murphy Company 2.0E 2.1E 2.2E LVL Technical Design Guide

Murphy Company is a company that manufactures wood products. Murphy Company LVL is Engineered Douglas-fir LVL, which has superior performance and durability, and is perfectly suited for spans bearing heavy loads and multi-span applications. Murphy Company LVL is cured in a controlled process in which water-proof adhesives boost stability and reduce warps and twists. All products are machine-ripped to generate uniform size and rigid, flat surfaces with inherently superior nail-holding characteristics.


Murphy Company 2.0E 2.1E 2.2E LVL Technical Design Guide - cover page
Brand
Murphy Company
Category
Other
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
1.4 MB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
39FE0D16080352C75B3C8B0D2639B0F1

About this manual

This document serves as a technical design guide for Murphy Company's Engineered Douglas-fir Laminated Veneer Lumber (LVL) products, specifically models 2.0E, 2.1E, and 2.2E. It details the superior performance and durability of these engineered wood products, which are designed for spans bearing heavy loads and multi-span applications. The guide emphasizes that the products utilize ultrasonically tested and graded Douglas fir veneer with water-proof adhesives to ensure dimensional stability and reduce warps.

What's inside

  • LVL Design Properties
  • Allowable Design Stresses
  • Floor Beams Application
  • Garage Door Headers
  • Modulus of Elasticity
  • General Notes
  • Design Assumptions

Specifications

Bending Stress (Fb)3100 psi
Horizontal Shear Stress (Fv)290 psi
Compression Perpendicular to Grain (Fc)750 psi
Compression Parallel to Grain (fc)3,200 psi
Modulus of Elasticity (E)2.0E, 2.1E, 2.2E

Frequently asked questions

What are the general notes for using this design guide?

All tables assume dry conditions, and calculations are based on NDS and IBC standards.

What is the maximum allowable beam deflection?

The maximum deflection is L/360 for live load and L/240 for total load.

What lateral support is required for the compression edge of beams?

Lateral support must be provided at 24 inches on center.

Download PDF (1.4 MB)