LK 4591 Floor Mount Stone Fountain Installation Guide

This is a document about 4591 model fountain installation instructions.


LK 4591 Floor Mount Stone Fountain Installation Guide - cover page
Brand
LK
Document type
Installation Guide
Language
English
Pages
4
File format
PDF
File size
58 KB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
D01319A30F486AE5CB313C6BBFD67BB4

About this manual

This guide provides step-by-step instructions for installing the LK 4591 Floor Mount Stone Fountain. It covers plumbing connections using 3/8" unplated copper tubing, electrical grounding precautions, mounting requirements, and stream height adjustment. The document also includes a parts list and troubleshooting tips for mineral deposits and flow regulation.

Important safety and compliance notes are included, such as checking local plumbing and electrical codes, using plastic drain fittings to avoid electrolysis, and ensuring the mounting structure can support a 300 lb load.

What's inside

  • Water Supply and Drain Connections
  • Electrical Grounding Precautions
  • Mounting Requirements
  • Stream Height Adjustment
  • Troubleshooting and Maintenance
  • Parts List

Specifications

Water Supply Tube3/8" O.D. unplated copper tube
Waste Pipe1-1/4" IPS
Operating Pressure Range20 psig to 105 psig
Stream Height AdjustmentFactory set at 45-50 PSI

Frequently asked questions

What type of tubing should be used for water supply?

Use 3/8" O.D. unplated copper tubing for water supply.

What is the operating pressure range for this fountain?

The fountain operates between 20 psig and 105 psig.

How do I adjust the stream height?

Remove items 7 and 8, then adjust the screw on item 17; clockwise raises the stream, counter-clockwise lowers it.

What should I do if mineral deposits clog the orifice?

Remove deposits with a small round file or small diameter wire, but do not file or cut the orifice material.