Allied Motion xDrive Series Digital Brushless Servo Drives User Manual

This manual describes the installation and operation of the xDrive series of digital brushless servo drives manufactured by Allied Motion Technologies, Inc.


Allied Motion xDrive Series Digital Brushless Servo Drives User Manual - cover page
Brand
Allied Motion
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
42
File format
PDF
File size
530 KB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
AC657DCB2D7680A378B7C5981194C351

About this manual

This user manual provides detailed instructions for installing, configuring, and operating the xDrive Series digital brushless servo drives. It covers wiring, motor commutation, fault protection, and troubleshooting procedures. The drives support multiple command modes and feedback types, including Hall sensors and incremental encoders. Safety precautions and environmental specifications are also included.

The manual includes tables and figures for specifications, connector pinouts, and wiring diagrams. It addresses setup parameters for current, velocity, and position loops, and explains fault detection and reset procedures. The document is intended for trained engineers and users familiar with servo drive systems.

What's inside

  • Safety
  • Inspection upon Receipt
  • Product Description
  • Features
  • Installation and Wiring
  • Motor Commutation and Feedback
  • Setup Guide
  • Faults and Troubleshooting
  • System Accessories
  • Revision History

Specifications

Input Voltage60-240 VAC, 50/60 Hz, single- or three-phase; 80 to 320 VDC
Continuous Output Power (240 VAC, single-phase)350 W, 700 W, 1400 W
Continuous Output Current4.0 A Pk (2.8 A RMS), 8.0 A Pk (5.6 A RMS), 16.0 A Pk (11.2 A RMS)
Supported Motor FeedbackHalls; Incremental Encoder + Halls
Operating Ambient Temperature0 to 45 °C
Motor Command Modescurrent mode, torque mode, velocity mode, position mode

Frequently asked questions

What motor feedback types are supported?

The drive can accept motor feedback from Halls only, or an incremental encoder with halls.

What are the supported motor command modes?

The motor command modes supported by the drive are current mode, torque mode, velocity mode, and position mode.

What is the operating ambient temperature range?

The operating ambient temperature range is 0 to 45 °C.

What is the maximum peak output current for 2 seconds?

The maximum peak output current for 2 seconds is 32.0 A Pk (22.4 A RMS).